NLRFM1 High fidelity FM Receiver87.5-108 MHz Range
Ø FM Receiver for rebroadcast applications or Station Monitoring Ø State of the art sound quality Ø Dynamic selectivity Ø 100 microvolts stereo sensitivity Ø Great performance in the presence of strong electromagnetic fields Ø Unbalanced audio mpx output Ø Bandpass filter included
This receiver is very versatile and can be use for re-broadcasting or as a monitoring unit for any broadcast station. The selective front end filter is built-in the unit and must be adjusted on the desire frequency.
TECHNICAL SPECIFICATIONSFrequency Range 87.5 –108 Mhz Modulation FM Class F3 VCO Spectrum tuning > 25 Mhz Channel Spacing 10 Khz Tuning Synthesized PLL Frequency Stability <2 ppm from 0° to 50° C ( 32° to 122° F) RF input connector “ N “ type RF input impedance 50 Ohms Maximum RF input Signal 0 dBm Muting level selectable - 100 dBm to 0 dBm (- 70 dBm standard) Rejection 1st Adjacent channel: typ. 20 dB; 2nd Adjacent channel typ. 50 dB IF Frequency 10.7 Mhz and 700 Khz Sensitivity 100 uV for a >68dB S/N; 10 uV for a >55 dB S/N; 5 uV for a >50dB S/N Selectivity 40 dB @ ± 600 Khz Base band 25 Hz – 60 Khz @ ± 0.5 dB S/N Ratio ( Stereo demod.) > 65 dB @ ± 75 Khz Image frequency rejection (tuner) > 50 dB Image frequency rejection (tuner + filter) > 80 dB
MPX OPERATION Output Connectors BNC Amplitude response ± 0.07 dB (20 Hz- 60 Khz ; ± 0.5 dB ( 60 Khz – 75 Khz) Stereo crosstalk >40 dB Total harmonic distortion < 0.2 % @ ± 75 Khz Output impedance 30 Ohms Earphone Impedance 10 Kohms
GENERAL CHARACTERISTICS Temperature Range -0° to 50° C (32° to 122° F) Power Supply 100 V to 250 V Power consumption < 50 VA Dimensions 483 mm (19”) x 44 mm (1.74 “) x 365 mm ( 14-1/2” ) Packaged Weight 4 Kg ( 8.8 lbs)
E-mail: info@NicomUsa.com |